Harlequin 1400FS Bunded Fuel Station
Diameter: 1570 mm
Height: 1850 mm
Weight: 147 kg
Capacity 1413 litres
NEW 2” BSP Lockable Fill Point with Screw Cap and Chain
NEW 4” Lockable Inspection Point with Plastic Screw Cap
NEW Choice of 12v (56lpm), 24v (56lpm), 110v (56lpm), 240v (56lpm) or 240v (72lpm) Electric Pump
NEW Choice of 10 micron Particulate Filtration or 30 micron Integrated Particulate and Water Filtration
NEW Mechanical Flow Meter with Resetable Batch Totaliser
Weatherproof Fuel Tank Vent
Oil Tank Contents Dipstick
Apollo Electronic Oil Tank Contents Gauge
LRC Failsafe Oil Tank Overfill Prevention Capability
Lockable Access
4 metre Fuel Delivery Hose with Three Stage Automatic Shut Off Nozzle
Emergency Isolation Switch
Bulkhead Light – 240v Models only
Factory Fitted Electrical Connection Point - 240v and 110v Models only
Battery Fly Leads – 12v and 24v Models only
|
| |
|
Harlequin 2500FS Bunded Fuel Station
Diameter: 2090 mm
Height: 1800 mm
Weight: 200 kg
Capacity: 2547 litres
NEW 2” BSP Lockable Fill Point with Screw Cap and Chain
NEW 4” Lockable Inspection Point with Plastic Screw Cap
NEW Choice of 12v (56lpm), 24v (56lpm), 110v (56lpm), 240v (56lpm) or 240v (72lpm) Electric Pump
NEW Choice of 10 micron Particulate Filtration or 30 micron Integrated Particulate and Water Filtration
NEW Mechanical Flow Meter with Resetable Batch Totaliser
Weatherproof Fuel Tank Vent
Oil Tank Contents Dipstick
Apollo Electronic Oil Tank Contents Gauge
LRC Failsafe Oil Tank Overfill Prevention Capability
Lockable Access
4 metre Fuel Delivery Hose with Three Stage Automatic Shut Off Nozzle
Emergency Isolation Switch
Bulkhead Light – 240v Models only
Factory Fitted Electrical Connection Point - 240v and 110v Models only
Battery Fly Leads – 12v and 24v Models only
|
| |
|
Harlequin 5000FS Bunded Fuel Station
Length: 2950 mm
Width: 2520 mm
Height: 2500 mm
Weight: 420 kg
Capacity: 5042 litres
NEW Choice of 12v (56lpm), 24v (56lpm), 110v (56lpm), 240v (56lpm) or 240v (72lpm) Electric Pump
NEW Choice of 10 micron Particulate Filtration or 30 micron Integrated Particulate and Water Filtration
NEW Premium quality Electronic Oil Tank Contents Gauge +/- 1% Accuracy - 110v and 240v Models Only
NEW Hydrostatic Oil Tank Contents Gauge - 12v and 24v Models Only
NEW Mechanical Overfill Prevention Valve - 12 and 24v Models Only
NEW Cabinet Drip Mat
Failsafe LRC Failsafe Overfill Prevention Capability
Offset 2" Fill Point with Lockable Screw Cap, Lever Type Isolation Valve and Non Return Valve
4” Inspection Point with Lockable Plastic Screw Cap
Fuel Tank Vent
Bund Warning Alarm
Lockable Access
6 metre Fuel Delivery Hose with Three Stage Automatic Shut Off Nozzle
Digital Flow Meter +/- 0.5% Accuracy with +/-0.2% Repeatability
Emergency Isolation Switch
Bulkhead Light – 240v Models only
Factory Fitted Electrical Connection Point - 240v and 110v Models only
Battery Fly Leads – 12v and 24v Models only
(Can be supplied complete with 80 user fuel management system at extra cost - see below. Please note that this system cannot be retrofitted at a later date.)
|
| |
|
Harlequin 5000FS FM Bunded Fuel Station
Specification as for 5000FS Bunded Fuel Station but with factory fitted 80 user, easy to use fuel management system. (240 volts only) Supplied with PC based software and 10 secure magnetic user keys (no PIN numbers required!)
SPECIAL OFFER Free on-site system commissioning (saves £350 plus VAT!)
|
| |
|
Harlequin 10000FS Bunded Fuel Station
Length: 3250 mm
Width: 2800 mm
Height: 3350 mm
Weight: 725 kg
Capacity: 9595 litres
NEW Choice of 12v (56lpm), 24v (56lpm), 110v (56lpm), 240v (56lpm) or 240v (72lpm) Electric Pump
NEW Choice of 10 micron Particulate Filtration or 30 micron Integrated Particulate and Water Filtration
NEW Premium quality Electronic Oil Tank Contents Gauge +/- 1% Accuracy - 110v and 240v Models Only
NEW Hydrostatic Oil Tank Contents Gauge - 12v and 24v Models Only
NEW Mechanical Overfill Prevention Valve - 12 and 24v Models Only
NEW Cabinet Drip Mat
Failsafe LRC Failsafe Overfill Prevention Capability
Offset 2" Fill Point with Lockable Screw Cap, Lever Type Isolation Valve and Non Return Valve
4” Inspection Point with Lockable Plastic Screw Cap
Fuel Tank Vent
Bund Warning Alarm
Lockable Access
6 metre Fuel Delivery Hose with Three Stage Automatic Shut Off Nozzle
Digital Flow Meter +/- 0.5% Accuracy with +/-0.2% Repeatability
Emergency Isolation Switch
Bulkhead Light – 240v Models only
Factory Fitted Electrical Connection Point - 240v and 110v Models only
Battery Fly Leads – 12v and 24v Models only
(Can be supplied complete with 80 user fuel management system at extra cost - see below. Please note that this system cannot be retrofitted at a later date.)
|
| |
|
Harlequin 10000FS FM Bunded Fuel Station
Specification as for 10000FS Bunded Fuel Station but with factory fitted 80 user, easy to use fuel management system. (240 volts only) Supplied with PC based software and 10 secure magnetic user keys (no PIN numbers required!)
SPECIAL OFFER Free on-site system commissioning (saves £350 plus VAT!)
SPECIAL OFFER Free on-site system commissioning (saves £350 plus VAT!)
|
| |
|
Diesel Fuel Replacement Filter Cartridge
Suitable for all standard Harlequin Fuel Stations and for diesel fuel.
We recommend you order one now as back up. The last thing you need is poor or no delivery due to a blocked filter!
Should be changed every 12 months
|
| |
|
|